Are there six details in the use of steel pipe medium frequency Induction heating furnace? If you know these six requirements, the service life of your induction heat treatment equipment will be extended by at least two to five years.

1. In case of overheating protection alarm during the use of steel pipe medium frequency induction heating furnace, the possible reasons are: too little cooling water, insufficient water quantity, poor water quality, water blockage, etc;

2. Steel pipe induction heating equipment is easy to stop suddenly during operation. The possible reasons are: the speed of the workpiece entering and leaving the induction coil is too fast, there is short circuit and ignition between the workpiece and the induction coil or the induction coil itself, the gap between the workpiece and the induction coil is too small, and the shape and size of the self-made induction coil are incorrect;

3. When the water shortage protection alarm occurs during the use of the steel pipe medium frequency induction heating furnace, the reasons are: the water pipe is connected reversely, the water pump power or pressure flow is insufficient, the water quality is poor, and the water channel is blocked;

long-bar-induction-heat-treatment-furnace-supplier-china

4. The overvoltage protection of steel pipe medium frequency induction heating furnace gives an alarm during use. The reason is that the grid voltage is too high, exceeding 10% of the rated voltage, and it is used when the power consumption is low;

5. When the over-current protection alarm occurs in the use of the steel pipe heating furnace, the reasons are: the shape and size of the self-made induction ring are incorrect, the distance between the workpiece and the induction ring is too small, the distance between the workpiece and the induction ring or the induction ring is too large, the ring is too small, the body has short-circuit ignition, and the prepared induction coil is affected by the customer’s metal fixture or nearby metal objects;

6. In case of phase loss protection alarm, the reasons may be: serious imbalance of three-phase power, lack of one-phase three-phase power, open circuit of air switch or power supply line, etc.

forever-furnace-manufacturers-china

Through the above introduction, I think you know the details of the use of steel pipe medium frequency induction heating furnace. FOREVER Electromechanical is a professional manufacturer of induction heating equipment. Professional engineers customize suitable induction heating equipment, induction heat treatment equipment, quality control heat treatment production line, etc. according to your requirements.