Regular maintenance and periodic maintenance of tubing induction heat treatment furnace
Forever Electromechanical Equipment Factory has been in the leading technical level in the same industry in China. The company’s product positioning is clear. Aiming at the rapid growth of tubing induction heat treatment furnace production, the production layout is adjusted actively, and the production efficiency is constantly improved by strengthening the product intelligence.
The periodic maintenance is also important for medium frequency tubing induction heat treatment furnace. Let’s see what to do.
1.Ensure that the tubing induction heat treatment furnace is specially operated, specially maintained and repaired. For general factories, electricians or operators can be capable after trained by factory.
2.Attention should be paid to the following two points in order to prevent large electric current impact from tubing induction heat treatment furnace.
A. Before switch on the main switch, firstly make sure that the panel power switch and the back air switch on the back of the machine is in off state, then turn on the air switch on the back of the machine and the panel power switch in turn.
B.Starting the tubing induction heat treatment furnace at empty load is not allowed in the high power. (that is to say, before power is switched on, the power is best transferred to the minimum. When the power is turned on, the power is increased according to need.)
3.Ensure the cooling water temperature, water pressure, water flow and water quality to achieve targets. The cooling water in the machine is multiway and parallel. If the road is blocked, the machine cannot alarm. The tubing induction heat treatment furnace should be cleaned after 1 months. The method: firstly use the appropriate high-pressure gas to dredge the circulating water pipe, then use the detergent to add the water according to the 1:40 proportion, and then clean the water with the water pump for 1 hours.
4.Frequently observe the flow of cooling water, if there is a lack, you should add immediately, otherwise it is easy to burn the transformer. Sweep the dust in the transformer regularly every month.
5. The fan is checked regularly, and the screen should be dusting once a week.
6. The inductor of tubing induction heat treatment furnace is cleaned after work every day.
7.Regularly add lubricating oil to the transmission parts of long bar induction heat treatment machine.
8.Check the ground wire regularly.
9, Sun exposure, rain, humidity, dust and so on should be avoided.